You can set these properties from the older 'Visa Assistant' I/O communication utility that ship with Agilent's I/O Libraries. Some older GPIB instruments do not respect the EOI (End-of-input) GPIB bus signal and instead rely on the linefeed character. For reading, set the VI_ATTR_TERMCHAR property to 10 and turn on the VI_ATTR_TERMCHAR_EN property so that reading will terminate when the linefeed character is received from the instrument.
#AGILENT TECHNOLOGIES 82350B PCI GPIB DRIVERS CODE#
> So, is that the problem from Klinger CC1.1 step motor controller? If the timeout error occurs during reading from the instrument you might try adding a linefeed character (ASCII code 10, ' n') to the end of each string you write to the instrument. The utility returned a timeout error VI_ERROR_TM0. > Then, I tried to send the commands using that agilent I/O configuration utility.īut it fails. > Although the computer can detect the CC1.1 step motor control with auto detecting its address, I can't control the motor by my Labview program. > I have used the Agilent I/O Configuration utility downloaded from the Agilent website. Agilent Gpib To UsbĪlbertpiero wrote: > Hi, I am now using the Agilent 82350 PCI GPIB card to control a Klinger CC1.1 step motor controller. You can so ask the manufacturer of the Klinger to help you Regards, FG. If you can give access to your instrument on the Internet (public IP ), I or some Klinger specialist can also program your Klinger remotely ( labview or labtab ). The allmighty GPIB genius should spread out of the lamp at some time and stay with you definitely. Needed ) and make sure the EOI signal is understood and sent by the 82350. Pay especially attention to add terminators ( rc lf etc.
#AGILENT TECHNOLOGIES 82350B PCI GPIB DRIVERS INSTALL#
) - install a free gpib software to make a check with an independent program ( is an example ) - find an Agilent voltmeter AG 34401A and replace your Klinger with it to eliminate Klinger-related problems - send an idn? String with both labview and labtab toolbar direct dialog and wait for an answer of the voltmeter When one of the software works, make sure of your klinger address and send a string command to your klinger.
#AGILENT TECHNOLOGIES 82350B PCI GPIB DRIVERS DRIVER#
2) To solve your problem, you might do the following: - verify that your Agilent board driver has been installed ( for instance re-install it, I mean SIC元2, VISA etc. I thought it was only possible ( at bus level ) with the NI boards and possible with some incompatibilities at VISA layer level with board of other manufacturers. Hi, 1) Are you sure it is possible to control a 82350 PCI GPIB board from LabVIEW? Please tell me how, I am interested. Figuring out how all objects (and creatures) interact with one another takes some doing, and as you might expect, some of it is more intuitive than others. There are a surprising amount of very effective scary moments, often when you least expect them. Which isn't to say there aren't any startling moments. Buffering provides I/O and system performance that is superior to direct memory access (DMA).
![agilent technologies 82350b pci gpib drivers agilent technologies 82350b pci gpib drivers](https://harddiskdirect.com/media/catalog/product/8/2/82350-66511.jpg)
The 82350B card de-couples GPIB transfers from PCI bus transfers.
![agilent technologies 82350b pci gpib drivers agilent technologies 82350b pci gpib drivers](https://i.ebayimg.com/images/g/fYcAAOSwcnpTmOnU/s-l640.jpg)
With a direct PCI computer connection, transaction overhead is minimized for the best overall performance. The 82350B is Agilent’s highest-performance GPIB interface. PCI GPIB Card Expand your connection using Keysight Open products give you the freedom to choose the right tools for your test solution and the assurance that they will all work together, every time. The Keysight 82350B is a high-performance IEEE-488 interface and software for 5v PCI-based PCs.
#AGILENT TECHNOLOGIES 82350B PCI GPIB DRIVERS DRIVERS#
I have downloaded and installed the instrument drivers for the HP3458A from ni instrument drivers.
![agilent technologies 82350b pci gpib drivers agilent technologies 82350b pci gpib drivers](https://i.ebayimg.com/images/g/gboAAOSw7qRd3smw/s-l640.jpg)
The GPIB card I have installed in my computer is Agilent Technologies 82350 PCI GPIB (I am not sure but I think this is actually a HPIB?).